Glossary and Course Review
Module 6 · Safety and Review

Glossary and Course Review

Review the core vocabulary of industrial pneumatics, follow the air from compressor to cylinder one more time, and test yourself across the whole course.

The Whole System

  1. M2 Compressor

    Screw, piston, centrifugal

  2. M2 Treat

    Receiver, dryer, filters, drains

  3. M2 Distribute

    Loop header, top drops

  4. M2 FRL

    Filter, regulate, maybe lubricate

  5. M4 Valve

    3/2, 5/2, 5/3

  6. M4 Flow control

    Meter-out at the cylinder

  7. M3 Actuator

    Cylinder, rotary, gripper, vacuum

Leaks, pressure drops, and wet air anywhere along this path show up as problems at the actuator.

Glossary

TermMeaning
3/2, 5/2, 5/3Valve naming: ports / positions
Coalescing filterRemoves fine oil aerosols and water droplets
Compression ratio(gauge pressure + 14.7) ÷ 14.7
CushionTrapped exhaust air that slows the piston near end of stroke
Double-actingCylinder driven by air in both directions
Double-solenoid valveValve with “memory”: stays in its last shifted position
Dump valveLockable 3/2 valve that blocks supply and exhausts downstream air
Duty cyclePercent of time a compressor can run loaded without overheating
FRLFilter, regulator, lubricator at the machine
Load/unload testMeasures leakage: T ÷ (T + t) with production off
Meter-outRestricting exhaust air to control cylinder speed
NC / NONormally closed / normally open valve
PDPPressure dew point: temperature where water condenses at line pressure
Pilot-operatedValve whose main spool is shifted by pilot air
psig / psiaGauge pressure / absolute pressure (gauge + ~14.7)
Quick exhaust valveDumps cylinder air directly at the port for speed
ReceiverStorage tank that buffers demand and drops out water
scfmFlow in standard cubic feet per minute
Side loadForce across the rod; destroys bushings and seals
Soft-start valveRamps up pressure gradually when air is restored
Venturi / ejectorMakes vacuum from a compressed air jet
VSDVariable speed drive compressor that matches output to demand

Formulas to Remember

WhatFormula
Cylinder extend forcePressure × π × (bore ÷ 2)²
Cylinder retract forcePressure × (piston area − rod area)
Absolute pressureGauge + 14.7 psi (at sea level)
Vacuum cup forceVacuum (psi) × cup area ÷ safety factor
Leakage %Loaded time ÷ (loaded + unloaded time) × 100
Leak costscfm × kW/scfm × hours × $/kWh

🧪 Try It: Capstone: Walk Down a Machine

Choose a pneumatic machine in your workplace (or a video of one). Produce a one-page walkdown:

  1. Supply: Where does its drop come off the header? What pressure does the FRL regulate to? Is there a lockable dump valve?
  2. Valves: How many? Single or double solenoid? Any 5/3 valves, and what center?
  3. Actuators: List each cylinder’s bore and estimate its extend force at the set pressure.
  4. Speed control: Meter-in or meter-out? Mounted at the cylinder?
  5. Leaks: Listen or use soapy water at couplings, FRLs, and exhausts. Estimate leak sizes.
  6. Stored energy: List every place energy remains after isolation.

You now have a maintenance baseline, a leak list, and the start of a lockout procedure.

🧠 Knowledge Check

1. Pressure determines an actuator's ___, and flow determines its ___.

2. Which dryer would you choose for an outdoor air line in a freezing climate?

3. What is the theoretical extend force of a 3-inch bore cylinder at 80 psi?

4. Air leaving a cylinder's rod side is restricted to control extension speed. This is called:

5. Air is restored after maintenance and a cylinder suddenly moves even though no button was pressed. Which valve type most likely caused this?

6. Which isolation device properly de-energizes a pneumatic machine?