Glossary and Course Review
Review the core vocabulary of industrial pneumatics, follow the air from compressor to cylinder one more time, and test yourself across the whole course.
The Whole System
- M2 Compressor
Screw, piston, centrifugal
- M2 Treat
Receiver, dryer, filters, drains
- M2 Distribute
Loop header, top drops
- M2 FRL
Filter, regulate, maybe lubricate
- M4 Valve
3/2, 5/2, 5/3
- M4 Flow control
Meter-out at the cylinder
- M3 Actuator
Cylinder, rotary, gripper, vacuum
Glossary
| Term | Meaning |
|---|---|
| 3/2, 5/2, 5/3 | Valve naming: ports / positions |
| Coalescing filter | Removes fine oil aerosols and water droplets |
| Compression ratio | (gauge pressure + 14.7) ÷ 14.7 |
| Cushion | Trapped exhaust air that slows the piston near end of stroke |
| Double-acting | Cylinder driven by air in both directions |
| Double-solenoid valve | Valve with “memory”: stays in its last shifted position |
| Dump valve | Lockable 3/2 valve that blocks supply and exhausts downstream air |
| Duty cycle | Percent of time a compressor can run loaded without overheating |
| FRL | Filter, regulator, lubricator at the machine |
| Load/unload test | Measures leakage: T ÷ (T + t) with production off |
| Meter-out | Restricting exhaust air to control cylinder speed |
| NC / NO | Normally closed / normally open valve |
| PDP | Pressure dew point: temperature where water condenses at line pressure |
| Pilot-operated | Valve whose main spool is shifted by pilot air |
| psig / psia | Gauge pressure / absolute pressure (gauge + ~14.7) |
| Quick exhaust valve | Dumps cylinder air directly at the port for speed |
| Receiver | Storage tank that buffers demand and drops out water |
| scfm | Flow in standard cubic feet per minute |
| Side load | Force across the rod; destroys bushings and seals |
| Soft-start valve | Ramps up pressure gradually when air is restored |
| Venturi / ejector | Makes vacuum from a compressed air jet |
| VSD | Variable speed drive compressor that matches output to demand |
Formulas to Remember
| What | Formula |
|---|---|
| Cylinder extend force | Pressure × π × (bore ÷ 2)² |
| Cylinder retract force | Pressure × (piston area − rod area) |
| Absolute pressure | Gauge + 14.7 psi (at sea level) |
| Vacuum cup force | Vacuum (psi) × cup area ÷ safety factor |
| Leakage % | Loaded time ÷ (loaded + unloaded time) × 100 |
| Leak cost | scfm × kW/scfm × hours × $/kWh |
Choose a pneumatic machine in your workplace (or a video of one). Produce a one-page walkdown:
- Supply: Where does its drop come off the header? What pressure does the FRL regulate to? Is there a lockable dump valve?
- Valves: How many? Single or double solenoid? Any 5/3 valves, and what center?
- Actuators: List each cylinder’s bore and estimate its extend force at the set pressure.
- Speed control: Meter-in or meter-out? Mounted at the cylinder?
- Leaks: Listen or use soapy water at couplings, FRLs, and exhausts. Estimate leak sizes.
- Stored energy: List every place energy remains after isolation.
You now have a maintenance baseline, a leak list, and the start of a lockout procedure.
1. Pressure determines an actuator's ___, and flow determines its ___.
Pressure × area gives force; how fast air can move in and out sets speed.
2. Which dryer would you choose for an outdoor air line in a freezing climate?
Refrigerated dryers give a PDP near 35–40 °F, which isn't low enough for freezing conditions. Desiccant dryers reach −40 °F or lower.
3. What is the theoretical extend force of a 3-inch bore cylinder at 80 psi?
Area = π × 1.5² ≈ 7.07 in². Force = 80 × 7.07 ≈ 565 lbf.
4. Air leaving a cylinder's rod side is restricted to control extension speed. This is called:
Restricting exhaust flow is meter-out, the standard for double-acting cylinders.
5. Air is restored after maintenance and a cylinder suddenly moves even though no button was pressed. Which valve type most likely caused this?
A double-solenoid valve remembers its last position and sends air there as soon as supply returns.
6. Which isolation device properly de-energizes a pneumatic machine?
A 3/2 dump valve both blocks supply and vents downstream air, and it can accept a lock.