Selecting the Right Hose
Use the STAMPED checklist to confidently select the correct hydraulic hose for any application — covering size, temperature, pressure, material compatibility, and delivery.
The STAMPED Method
When selecting or replacing a hydraulic hose, use the acronym STAMPED as your checklist. It ensures you consider every critical factor before choosing a hose assembly.
- S Size
Tube ID as a dash number
- T Temperature
Fluid, ambient, and system heat
- A Application
Equipment, routing, standards
- M Material
Tube, cover, coupling, and O-ring compatibility
- P Pressure
Working pressure ≥ system pressure + spikes
- E Ends
Couplings that match the ports
- D Delivery
ID sized for the required flow
S — Size (Dash Numbers)
Hose size is identified using Dash Numbers — the industry standard for describing hose and coupling size.
- Dash numbers represent the hose Inside Diameter (ID) in sixteenths of an inch
- A -4 hose = 4/16” = ¼” ID
- A -8 hose = 8/16” = ½” ID
⚠️ Do not use the hose OD to identify its size. Different hose constructions vary in wall thickness and OD — always measure the ID.
Dash Numbers Reference Table
| Dash No. | ID (Inches) | ID (mm) |
|---|---|---|
| -2 | 1/8 | 3.2 |
| -3 | 3/16 | 4.8 |
| -4 | 1/4 | 6.4 |
| -5 | 5/16 | 7.9 |
| -6 | 3/8 | 9.5 |
| -8 | 1/2 | 12.7 |
| -10 | 5/8 | 15.9 |
| -12 | 3/4 | 19.0 |
| -16 | 1 | 25.4 |
| -20 | 1-1/4 | 31.8 |
| -24 | 1-1/2 | 38.1 |
| -32 | 2 | 50.8 |
Replacing a Hose — Determining the Right Size
- Easiest method: Read the layline printed on the original hose
- If layline is unreadable: Cut the original hose and measure the inside diameter
- Also note: Count and identify the number of reinforcement layers
T — Temperature
You must consider three temperature factors:
- a) Fluid temperature — the temperature of the fluid being conveyed
- b) Ambient temperature — the temperature of the surrounding environment (e.g., near a hot manifold)
- c) System temperature — heat generated by the hydraulic system itself (affected by hose length, friction, and hose size)
Important Temperature Rules
⚠️ Never exceed the manufacturer’s maximum operating temperature. Doing so risks equipment breakdown and injury.
- Intermittent temperature surges (up to 10% of operating time) are acceptable
- Do NOT expose a hose to maximum temperature and maximum working pressure at the same time — this drastically shortens hose life
- When routing near hot manifolds, protect the hose with a heat shield
A — Application
Most of the time you simply duplicate the original hose. When that’s not possible, answer these questions:
- Did the original hose give adequate service life?
- Where will the hose be used? What equipment type?
- What are the working and surge pressures?
- Is it a suction application?
- What are the fluid and ambient temperatures?
- Is the fluid compatible with the hose?
- What are the routing requirements and minimum bend radius?
- Are there government/industry standards to meet (USCG, DOT/FMSS, MSHA)?
- Is non-conductive hose required? (Critical for aerial equipment)
- Is excessive abrasion expected?
- What is the expected service life?
For gaseous applications (where permeation can occur), exercise additional caution in selecting the proper hose.
M — Material to Be Conveyed
The hose tube, cover, and couplings (including O-rings) must all be chemically compatible with the fluid.
Permeation
Permeation is the seepage of fluid through the hose wall — it results in fluid loss and can occur with any fluid. If permeation through the tube and reinforcement is likely, you can pinprick the hose cover to prevent fluid buildup and blistering (commonly done in pressure washer applications to release steam).
Volatile Fluids — Handle with Extra Care
These fluids require special attention due to their volatility. Improper hose selection creates liability and environmental risk:
- Liquid and gas fuels
- Refrigerants (134A)
- Fuel oil
- Natural gas
Note: All block-type couplings contain Nitrile O-Rings — these must also be compatible with the system fluid.
P — Pressure
You must know the system pressure, including pressure spikes. The hose working pressure must be equal to or greater than the system pressure.
Gates does NOT recommend using hose on applications where pressure spikes exceed the published working pressure of the hose.
Burst pressure is for destructive testing only — not for operational use. The minimum burst pressure is typically 4× the maximum working pressure.
Two Types of Pressure Systems
| Type | Description | Example |
|---|---|---|
| Static | Confined liquids perform work; force multiplied between containers | Hydraulic jack |
| Dynamic | Fluid-in-motion transfers energy to a driven element | Backhoe |
Impulse vs. Spike
- Impulse — a pressure surge usually caused by the hydraulic pump
- Spike — a sudden dramatic increase in pressure for a short period (e.g., a backhoe hitting a rock while digging)
Pressure Drop
Pressure drop is the difference between fluid pressure entering one end of a hose assembly and exiting the other. It occurs naturally but must be managed.
Causes of pressure drop:
| Factor | Effect |
|---|---|
| Friction | Fluid rubbing against hose walls and couplings |
| Viscosity | Thicker fluids drop more pressure |
| Ambient temperature | Cold = higher viscosity = more drop |
| Fluid temperature | Warmer fluid = thinner = less drop |
| Hose length | Longer = more friction = more drop |
| Hose ID (size) | Smaller ID = higher velocity = greater drop |
| Couplings/adapters | Bends and bore changes increase drop |
| Flow rate | Higher flow = greater drop for same size hose |
Example: If your system needs 4,000 psi output and the pressure drop is 150 psi, your input pressure must be 4,150 psi.
E — Ends of Couplings
The coupling ends must match the ports your hose assembly connects to. Consult the Gates Crimp Data Chart for recommended hose and coupling combinations. (Couplings are covered in detail in Module 4.)
D — Delivery (Quantity and Volume)
The hose must be sized to transport the required volume of fluid efficiently.
- Under-sizing a hose → increased pressure loss and heat
- Over-sizing a hose → unnecessary cost, weight, and bulk
If your replacement hose has the same ID as the original, the system is most likely properly sized.
Gates SAE Hose Nomenclature
Gates hose part numbers follow a standardized naming convention that tells you the hose size, spec, and cover type at a glance.
Standard SAE Nomenclature — Example: 8G2
| Position | Value | Meaning |
|---|---|---|
| 8 | Dash size | 8/16” = ½” ID |
| G | SAE 100R Spec | SAE 100R2 (2-wire braid) |
| 2 | Cover type | Thin cover, no skiving required |
Gates MegaSys® Nomenclature
MegaSys® hoses have half the bend radius of their SAE counterpart — making them significantly more flexible.
Benefits of MegaSys®
- Reduces hose length requirements up to 47%
- Decreases inventory requirements
- Routes easily in small spaces
- Fewer bent tube couplings needed
- Easier to plumb and bend than conventional hoses
MegaSys® Nomenclature — Example: 8M3K
| Position | Value | Meaning |
|---|---|---|
| 8 | Dash size | 8/16” = ½” ID |
| M | MegaSys® | ½ SAE bend radius |
| 3K | Pressure rating | 3,000 psi (K = Roman numeral for 1,000) |
MegaSys® Product Family
| Product | Notable Feature |
|---|---|
| C12M | MegaSpiral — high pressure spiral |
| M2T | MegaFlex — two-wire textile braid |
| M3K | Standard MegaSys 3,000 psi |
| M4K+ | Exceeds 6,000 impulse cycles |
| GMV | Global MegaVac® — vacuum/suction |
| M5K | 5,000 psi rating |
| M6K | 6,000 psi rating |
1. What does the 'S' in STAMPED stand for, and how is hose size measured?
S = Size. Hose size is expressed as a Dash Number representing the ID in sixteenths of an inch. A -8 hose has a ½" (8/16") inside diameter.
2. What is the dash number for a hose with a ¾" inside diameter?
-12 = 12/16" = ¾". Dash numbers represent the ID in sixteenths of an inch.
3. Which temperature rule is correct when selecting a hydraulic hose?
Exposing a hose to maximum temperature AND maximum pressure simultaneously drastically shortens its service life. Intermittent surges (up to 10% of operating time) are acceptable.
4. In the Gates SAE hose code '8G2', what does the '8' represent?
The first number is the dash size. '8' = 8/16" = ½" ID. 'G' is the SAE spec (100R2), and '2' indicates a thin cover requiring no skiving.
5. What is the main advantage of Gates MegaSys® hoses over standard SAE hoses?
MegaSys® hoses have half the bend radius of their SAE counterpart. This flexibility allows easier routing, shorter hose lengths (up to 47% reduction), and fewer bent tube couplings.
6. What happens when you under-size a hydraulic hose?
Under-sizing a hose creates a smaller ID, which increases fluid velocity and results in greater pressure drop and heat generation. Over-sizing adds cost, weight, and bulk.