Crimpers & Crimper Troubleshooting
Module 7 · Crimpers & Crimper Troubleshooting

Crimpers & Crimper Troubleshooting

Understand how a hydraulic crimper works, set one up correctly, maintain it properly, and solve the most common problems with the PowerCrimp® 707, OmniCrimp® 21, MobileCrimp® 4-20, and GC32-XD™.

How a Crimper Works

A crimper is a hydraulic ram. Here’s how it operates:

PumpMotorReservoir (tank)pressurized fluidCylinderPistonRodPusherTapereddie coneDies closeon the ferruleHose + fittingram moves down
  1. The pump pressurizes fluid
  2. Pressurized fluid flows to the cylinder, extending the piston
  3. The piston drives the rod and pusher down onto the tapered die cone
  4. The die cone’s taper forces the dies together, crimping the fitting onto the hose

Crimpers come in many configurations — vertical (bottom- or top-loading), horizontal, or angled. The operating principle is the same regardless of orientation.


Pump Types

Pump TypeMaintenance Requirement
Electric over hydraulicCheck fluid level monthly
Air over hydraulic1–2 drops of oil in air chamber daily; check fluid level monthly
Hand operatedCheck fluid level monthly

Crimper Set-Up

  1. Remove the crimper from its shipping container
  2. Position on a stable surface
  3. Connect the hydraulic hose assembly to the crimper and pump (refer to pump manual for port connection)
  4. Install the breather cap in the reservoir tank if needed
  5. Make the proper electrical connections
  6. Bleed any air from the system (follow procedures in the crimper operating manual)
  7. Lubricate all metal-to-metal sliding surfaces (dies, cones, die shoes) with the recommended lubricant
  8. Check calibration; re-calibrate as required
  9. Mail in the equipment registration form — ensures updated crimp data is forwarded to you

Crimper Maintenance

Proper maintenance keeps a crimper accurate and safe. Poorly maintained crimpers produce poorly-performing assemblies that can blow apart and cause injury.

Maintenance TaskDetail
LubricationReapply lubricant to metal-to-metal sliding surfaces when surfaces become shiny
CalibrationCheck every month — especially when you notice a change in crimp diameter
Hose assemblyCheck the hose connecting pump to cylinder; replace if needed with a properly-rated assembly
Fluid levelKeep within ½” from top of tank opening; prevents air from entering the system
Die wear and storageInspect for indentations, chips, cracks, gouges; store in racks or original packaging
CleaningRemove debris with a clean shop rag — dirt contaminates fluid and damages crimp components
Oil change and bleedingChange fluid periodically; fluid viscosity degrades under heat and high usage

Crimper Troubleshooting

The three most common crimper problem categories are:

  1. Cylinder seal — seals between piston and cylinder may leak or roll over time
  2. Electrical — power source compatibility issues; wiring problems
  3. Pump — debris in fluid causing stuck valves; cold temperature thickening fluid; air in system
Crimper problemCylinder seal• Ram stuck or won’t return• Fluid leaking at cylinder• Ram won’t fully extendFirst check:Check fluid level + temp,replace seal kitElectrical• Display blank or wrong• Won’t plug into power unit• Pump motor won’t startFirst check:Check wiring and matchingvoltage (115 V / 230 V)Pump• Stuck valves (debris in fluid)• Sluggish in the cold• Air in the systemFirst check:Clean fluid, warm up,bleed air

PowerCrimp® 707 Troubleshooting

ProblemSolution
Ram stuck, won’t returnSlowly loosen the hose at the pump (catch escaping fluid); if fluid escapes, the check valve may be stuck — contact Gates rep; if no fluid escapes, replace piston seal with proper seal kit
Digital display is blankCheck all wiring connections — wrong voltage will damage the display; replace if needed
Digital display is incorrectCheck electrical connections including back of display; check calibration; replace switch box
Cylinder leaking fluidDisassemble per seal replacement instructions; check cylinder wall for scoring; if damaged, replace cylinder; if not, replace worn seal
Broken die fingers or coneCheck crimp specs (proper die, hose, cone, settings); check calibration; replace broken parts. NOTE: Never drop dies — dropping can break them or damage the cone
Crimper won’t plug into power unitCheck voltage rating on both pump and crimper — 115-volt and 230-volt connectors differ; both must match
Over- or under-crimpingCheck calibration per operating manual; adjust actuator rod or switch box position; check crimp specifications

⚠️ Voltage Warning: If the PowerCrimp® 707 pump is changed to 230V, a new 230V cord assembly (78748) must be installed at the same time. If the new cord is not used, the 230-volt supply will burn out the digital readout within minutes.


OmniCrimp® 21 Troubleshooting

ProblemSolution
Numbers won’t display on digital readoutTurn the JOG switch to reverse position; once RAM recycles, readout is ready
Dies won’t stay in die shoesCheck and adjust the detente — must be just above the base of the die shoe. Use the detente wrench (inside die shoe grooves): clockwise to lower, counter-clockwise to raise
Pump will not shut offFaulty computer panel — return to manufacturer; contact Gates Application Engineer for instructions
Crimp OD out of specThe OmniCrimp 21 is pre-calibrated before shipping and should not need re-calibration. If OD is off, adjust the crimp setting on the crimp chart. If re-calibration is truly needed, contact Gates Application Engineer

MobileCrimp® 4-20 Troubleshooting

ProblemSolution
Ram will not fully extendCheck hydraulic oil level; oil temperature must be between +40°F and +120°F
Ram will not retractUnplug pump (safety first); carefully loosen hose at pump — if ram retracts, pump valve may be stuck or need replacing
Pump motor will not startCheck electrical connections
Setting will not changeLocking switch may be engaged — move switch to the left
Light and buzzer do not workReplace controller batteries; refer to Maintenance section; replace controller if needed

GC32-XD™ Troubleshooting

ProblemSolution
Pump motor will not startCheck electrical connections
Setting will not changeLocking switch may be engaged — move switch to the left
Will not hold crimp calibrationFlange head bolts are loose — check torque to 330 Nm (2,900 in-lbs) every six months
Red LED flashing rapidlyProblem with electronics in control panel — refer to safety and operating manual

🧠 Knowledge Check

1. In a hydraulic crimper, what is the role of the tapered die cone?

2. How often should you check a crimper's calibration?

3. The PowerCrimp® 707 ram is stuck and won't return. What is the first step?

4. When should die lubricant be reapplied on a crimper?

5. The GC32-XD™ will not hold its crimp calibration. What is the likely cause?