Glossary & Level 201 Review Quiz
Review key terminology from the Gates Hydraulics 201 series and test your full-course knowledge with the official Level 201 interactive review quiz.
The Whole Job at a Glance
Every module in this course is one stage in the life of a hose assembly. Use this map to place each glossary term in context as you review.
- M1 Understand
Tube, reinforcement, cover
- M2 Select
STAMPED + hose nomenclature
- M3 Apply
Pressure range, fluid, storage
- M4 Identify
Couplings, threads, seat angles
- M5 Assemble
Measure, cut, clean, crimp
- M6 Install
Ports, routing, troubleshooting
- M7 Maintain
Crimper care + calibration
Key Glossary Terms
Below are the most important terms from this course. Review them before taking the final quiz.
| Term | Definition |
|---|---|
| Abrasion (Hose) | Wearing, grinding, or rubbing away of material from the hose cover |
| Accumulator | Pressurized storage container for fluids; absorbs surges and maintains constant pressure |
| Ambient Temperature | Temperature of the hydraulic system’s surrounding environment |
| Bend Radius | Radius measured between the innermost surfaces of a curved hose; minimum bend radius is how far the hose can bend and still meet impulse test requirements |
| Bend Restrictors | PVC sleeves near the coupling to reduce stress at the hose/coupling interface and prevent kinking |
| Bite Sleeve | Internal sleeve used in flareless assemblies and standpipe couplings |
| Block Style Fittings | Use bar stock to orient the desired angle; increase pressure drop more than tube fittings |
| BSPP | British Standard Pipe Parallel — straight threads, 30° seat, O-ring or soft metal washer seal |
| BSPT | British Standard Pipe Tapered — tapered threads; seal made on threads; identical to Japanese tapered pipe thread |
| Buffing | Partial removal of the hose cover (to a specific diameter) to permit coupling insertion; uses a grinding wheel |
| Burst Pressure | Pressure that ruptures a hose; for testing purposes only — DO NOT use hose above published working pressure |
| C (Cutoff Length) | The portion of a coupling NOT inside the hose; used to calculate cut hose length |
| Caliper | Tool to measure ID and OD within a thousandth of an inch |
| Chemical Resistance | Index rating how well a hose compound endures contact with chemicals (Gates ratings: 1 = continuous, 2 = temporary, NR = not recommended) |
| Crimp | Method of permanently attaching hose couplings by compressing the ferrule |
| Crimp OD | Outside diameter of the ferrule after crimping; measured with calipers at the ridges |
| Dash Size | Industry standard for hose size — ID in 1/16” increments (e.g., -8 = ½”) |
| DIN | Deutsch Industrie Norme — German standards for couplings and fittings |
| DOT/FMVSS | Department of Transportation Federal Motor Vehicle Safety Standards for hydraulic, air, and vacuum brake hose |
| Dynamic Pressure | Pressure that fluctuates as the hydraulic system works |
| Effusion | Seepage of chemical molecules through the hose wall |
| Electrostatic Discharge (ESD) | Release of static electrical energy that can build up on insulated objects; can damage sensitive parts or create pinholes in PTFE hose |
| EnviroFluid™ | Gates hose line with nitrile tube for biodegradable fluids up to 250°F |
| Ferrule | The outer shell of a two-piece coupling that fits over the hose end and is crimped to hold the assembly together |
| Field Attachable Couplings | Reusable couplings installed without crimping equipment; DO NOT re-use these components |
| Fitting | A connector or closure for fluid power lines and ports |
| Fluid Compatibility | The hose assembly (tube, cover, reinforcement, and couplings including O-rings) must all be chemically compatible with the fluid |
| Flow Rate (GPM) | Amount of fluid measured in gallons per minute flowing through a hose |
| Friction (Fluid) | Rubbing of fluid against hose walls; primary cause of pressure drop and heat generation |
| Galvanic Action | Chemical reaction producing electrical current when two dissimilar metals are used together; weakens connections |
| GAZ | French coupling standard using 24° flare with metric fine threads |
| Hose Size | The ID (nominal inside diameter); expressed in dash numbers (sixteenths of an inch) |
| Hydraulic Cylinder | Component that performs work; an outer shell with an inner metal tube that extends and retracts |
| Hydrodynamic | Hydro + Dynamic = liquids actively in motion |
| Hydrostatic | Hydro + Static = liquids having no motion; force multiplication through static confined liquids |
| ID | Inside Diameter |
| Impulse | Pressure surge usually caused by the hydraulic pump |
| JIC 37° Flare | Joint Industry Conference; 37° flare seat; most common high-pressure fitting in North America |
| MegaCrimp® | One-piece permanent coupling with ferrule attached to stem |
| MegaSys® | Gates hose family with ½ SAE bend radius |
| Minimum Bend Radius | Tightest bend a hose can make and still pass SAE impulse testing at minimum bend radius |
| MSHA | Mine Safety and Health Administration — specifies flame resistance for underground mining hose |
| NPTF | National Pipe Taper Fuels — tapered threads that seal by deforming on the threads |
| OD | Outside Diameter |
| O-Ring Boss | Straight-thread fitting that seals with an O-ring compressed against the face of the port |
| Operating Pressure (PSI) | The hose must be capable of continuously handling system pressure including surges and spikes |
| Permeation | Seepage of fluid through the hose wall |
| Power Crimp® | Two-piece permanent coupling (separate stem and ferrule) |
| Pressure Drop | Difference in pressure between fluid entering and exiting a hose assembly; caused by friction, viscosity, length, size, and fittings |
| Pressure Spike | Sudden dramatic pressure increase (e.g., backhoe hitting a rock) |
| PTFE | Polytetrafluoroethylene — excellent high-temperature and chemical-resistance properties |
| Reinforcement | The structural layer of a hose (between tube and cover) that provides pressure resistance |
| Reservoir | Stores fluid; keeps oil clean; controls temperature; removes air |
| SAE | Society of Automotive Engineers — establishes American standards for hydraulic hose |
| Skive | Removing the rubber cover of a hose to expose the reinforcement where the fitting attaches |
| Sleeving | Protective covering for hoses; most common is nylon |
| Spike | See Pressure Spike |
| STAMPED | Acronym for hose selection: Size, Temperature, Application, Material, Pressure, Ends of couplings, Delivery |
| Static Pressure | Steady-state pressure in a confined system |
| Stem | The inner part of a coupling inserted into the hose |
| Swage | Similar to crimping but the coupling is forced into stationary dies |
| TuffCoat™ | Gates corrosion-resistant coupling plating — 400+ hours rust protection |
| Tube | Innermost hose layer; carries the fluid; determines hose size (ID) |
| USCG | United States Coast Guard — specifies requirements for marine hose (SAE J1475 and J1942) |
| Viscosity | Measure of a fluid’s ability to flow; higher viscosity = thicker fluid = greater pressure drop |
| Working Pressure | Maximum continuous operating pressure; hose must meet or exceed the system pressure including surges |
Level 201 Review Quiz
This is the official review quiz from the Gates Hydraulics 201 textbook, adapted into an interactive format. Test your knowledge across all modules!
1. Identify the stem style: G20
G20 = GlobalSpiral™. The full stem style codes are: G20 = GlobalSpiral™, G25 = MegaCrimp®, G40 = C14 (PTFE), G45 = PolarSeal®, G9 = Quick Disconnects.
2. What is the obvious physical difference between an SAE 45° Flare and a JIC 37° Flare coupling?
Gates puts a single notch on each hex on the SAE 45° flare male and female to differentiate them. JIC 37° male and female have no markings on the hex nut. Always measure the seat angle to confirm.
3. NPTF and BSPT couplings look similar. Name one reason they are NOT interchangeable.
NPTF and BSPT are not interchangeable for two reasons: (1) the thread pitch is different in most sizes, and (2) the thread angle on NPTF is 60° vs 55° on BSPT.
4. What does STAMPED stand for, and why is it important?
STAMPED = Size, Temperature, Application, Material, Pressure, Ends of couplings, Delivery. It is the complete 7-factor checklist used to select the correct hose assembly for any application — ensuring nothing critical is missed.
5. What is pressure drop?
Pressure drop is the difference between the fluid pressure entering one end of a hose assembly and the pressure exiting the other end. It is caused by friction, fluid viscosity, hose length, hose size, and fittings.
6. Hose layline reads: 8M3K. What is the bend radius of this hose?
8M3K = MegaSys® (M) 3,000 psi (3K) in -8 dash size (½" ID). The 'M' designates MegaSys®, which has half the bend radius of its SAE counterpart — the key advantage of the MegaSys® family.
7. Identify by pressure rating: EFG6K
EFG6K is an Extremely High-Pressure hose with 6,000 psi operating pressure in all sizes. It meets SAE 100R15 and is used for hydrostatic transmissions, snow groomers, and off-road construction equipment.
8. What is a dash size? How big is a -8 hose?
Dash size is the industry standard for measuring hose and coupling ID in 1/16" increments. A -8 hose has an ID of 8/16" = ½". This is also used for coupling and adapter sizing.
9. Identify this coupling: G25100-0808
G25 = MegaCrimp® series; 100 = thread configuration (Male Pipe/NPTF – 30° cone seat); 08 = stem size (-8 = ½"); 08 = thread size (-8 = ½"). Full description: MegaCrimp® Male Pipe coupling, ½" stem, ½" thread.
10. A 24° cone is found on standpipe (compression tube) couplings and flareless assemblies. Where else is a 24° cone used?
A 24° cone is also used on many high-pressure applications. A metric standpipe, metric bite sleeve, and proper metric nut provide the same 24° compression termination as German DIN (Light and Heavy), French GAZ, and Kobelco fittings.
11. A Japanese tapered pipe thread coupling looks identical to a British BSPT coupling. Can you safely interchange them?
Yes — the Japanese tapered pipe thread coupling is identical to and fully interchangeable with the British BSPT (tapered) coupling. Gates uses only one description (BSPT) for both because they are the same fitting.
12. A Komatsu 30° flare parallel thread coupling is dimensionally identical to a Japanese 30° flare parallel thread coupling. Why aren't they interchangeable?
Except for the threads, the Komatsu style 30° flare is dimensionally identical to the Japanese JIS 30° flare. However, Komatsu uses metric fine threads while JIS uses BSPP (British Standard Pipe Parallel) threads — making them incompatible.
13. A metric standpipe has three components. What are they?
A metric standpipe assembly consists of three pieces: the male fitting body (standpipe), the bite sleeve, and the nut. Tightening the nut compresses the bite sleeve onto the tube of the standpipe, making the seal.
14. If you cannot read the layline on the hose you are replacing, how do you decide which replacement hose to recommend?
If the layline is unreadable, cut the original hose and measure the inside diameter to determine the dash size. Also count and identify the number of reinforcement layers to determine the hose construction and pressure rating.
15. We know not all foreign couplings have metric threads. There are two foreign thread forms. One is metric. What's the other?
The two foreign thread forms are metric and Whitworth (also called BSP or British Standard Pipe). It is not true that all foreign threads are metric — British and some German threads use the Whitworth system.
16. If you measure the ID of an SAE 100R5 (C5) hose and specify a -8 coupling for it, why won't the coupling fit?
Dash sizes for SAE 100R5 (C5) and SAE 100R14 (C14) hoses are based on the tube OD, not the ID. All other hoses use ID-based dash sizes. This exception means measuring the ID of a C5 hose will not give you the correct dash size for coupling selection.